Technical Specifications

ElectricalInput voltage: 12 V DC (720-012PP) / 24 V DC (720-024PP); Input voltage range: 10-15 V (720-012PP) / 20-30 V (720-024PP); Constant output power: 150 W; Peak output power: 300 W; Maximum input current: 18 A (720-012PP) / 10 A (720-024PP); Output voltage: 230 V AC pure sine wave; Output frequency: 50 Hz; Idle current consumption: 0.5 A (720-012PP) / 0.3 A (720-024PP); Low voltage alarm: 10.5 V (720-012PP) / 21 V (720-024PP); Low voltage shutdown: 10 V (720-012PP) / 20 V (720-024PP); Minimum socket/cable/fuse rating: 15 A
Gas Or PressureNot applicable
Capacities DimensionsDimensions: 190 x 120 x 62 mm; Weight: 1.2 kg; Maximum ambient temperature: 50°C ± 5°C

Master Troubleshooting & Diagnostics Matrix

Error Code / IndicatorSymptom / MeaningStep-by-Step DIY FixSuggested Actions
N/A
The inverter does not work. The status indication LED is off.
Possible Cause: Short circuit for five consecutive times, or insulation faults, breaks, or loose connections at the live cables.
The device fuse must be replaced by an authorized service agent. Check live cables for insulation faults, breaks, or loose connections.DIY Check / Tech Fallback
N/A
The inverter does not work. The status indication LED lights up red due to high output current or short circuit.
Possible Cause: Too many connected loads or a generated short circuit.
Reduce the connected loads. The device fuse must be replaced by an authorized service agent after being triggered by excess current.Professional Intervention Required
N/A
The inverter does not work. The status indication LED lights up red due to high temperature shutdown.
Possible Cause: Internal temperature exceeds cut-off value or air inlets/outlets are obstructed.
Switch off the inverter and connected loads, check that air inlets/outlets are unobstructed, and allow the inverter to cool down.DIY Safe
N/A
The inverter does not work. The status indication LED lights up red due to overvoltage shutdown.
Possible Cause: Battery voltage too high (Cut-off: 16.5V for 12V systems, 33V for 24V systems).
Reduce connected voltages. Inverter restarts automatically when voltage drops to restart value (15.5V for 12V, 31V for 24V). If error persists, increase cable cross-sections and reduce cable length.DIY Safe
N/A
The inverter does not work. The status indication LED lights up red due to undervoltage shutdown.
Possible Cause: Battery voltage too low (Cut-off: 10.3V for 12V systems, 20.6V for 24V systems).
Allow the battery to recharge slowly. Inverter restarts automatically when voltage exceeds restart value (11.8V for 12V, 23.6V for 24V).DIY Safe
N/A
Inverter does not switch to normal operation from energy-saving mode automatically
Possible Cause: Connected load is below the set threshold (S2 DIP switch set to OFF requires >= 45 W, ON requires >= 80 W)
Ensure connected load meets or exceeds the active threshold or adjust DIP switch S2 accordingly.DIY Safe
N/A
Energy saving mode status cannot be changed
Possible Cause: Remote control, ENB+ pin is actively connected, or complete on-off cycle was not performed
Perform a complete on-off cycle or disconnect remote/ENB+ control before altering the mode.DIY Safe
N/A
No output voltage, no LED lights up
Possible Cause: No contact to the battery or defective fuse (in the inverter or vehicle-side)
Check contact and cable. Have an electrician change the fuse.DIY Check / Tech Fallback
N/A
No output voltage, green and red LED light, power consuming device is switched off
Possible Cause: Battery voltage less than 11 V (MSI212/MSI412) or 22 V (MSI224/MSI424), poor contact to the battery, or input voltage too high
Charge the battery (start the engine). Clean the contacts. Check and reduce the input voltage.DIY Safe
N/A
No output voltage, green and red LED light, power consuming device is switched on
Possible Cause: Overheating or inadequate cable connection (cross section too small or poor contact)
Switch off power consuming devices, let inverter cool down, ensure ventilation slots are clear, and lower ambient temperature. Use a cable with a larger cross-section and check contacts.DIY Safe
N/A
The device switches on and off repeatedly (up to five times, then the inverter is switched off)
Possible Cause: Excessive load
Switch off the device, reduce the load, and switch on the device again.DIY Safe
N/A
No output voltage, green and red LED light (steady)
Possible Cause: Excessive load, short circuit, or electrical wiring error
Switch off the device, reduce load or remove short circuit, check electrical wiring, and switch on again.DIY Safe
N/A
The inverter switches off when the consumer is switched on, red Status LED lights
Possible Cause: Starting current too high
Compare the device power requirement with the maximum power of the inverter.DIY Safe
N/A
LED Input Level quick flashing (Red)
Possible Cause: Input voltage is too high (> 15.0 V for 12V DC or > 30.0 V for 24V DC)
Check the input voltage and reduce it.DIY Safe
N/A
LED Input Level slow flashing (Red)
Possible Cause: Input voltage is too low (< 10.6 V for 12V DC or < 21.2 V for 24V DC)
The battery needs recharging. Check the cables and connections.DIY Safe
N/A
LED Input Level occasional flashing
Possible Cause: Overheating (internal temp > 60 °C or cooling element temp > 95 °C)
Switch off the inverter and the load. Wait about 5 - 10 minutes for reset, ensure better ventilation, and switch back on.DIY Safe
N/A
Load Status LED constantly lit (Red)
Possible Cause: Short circuit, reversed polarity, or excessive load
Switch off the inverter and remove the load. Switch back on without load to test. For MSI1812T, MSI1812TOE, and MSI1824T, press in the device fuse by hand after it triggers. Check cables and connections.DIY Safe
N/A
LED flashes quickly (Orange)
Possible Cause: Input voltage is too high
Check the input voltage and reduce it.DIY Safe
N/A
LED flashes slowly (Orange)
Possible Cause: Input voltage too low
Recharge the battery. Check the cables and connections.DIY Safe
N/A
LED flashes occasionally (Red, double flash)
Possible Cause: Inverter overheated
Switch off the inverter and consumer. Wait 5 to 10 minutes, ensure better ventilation, reduce load, and restart without consumers first.DIY Safe
N/A
LED constantly lit (Red)
Possible Cause: Short circuit, reversed polarity, or excessive load
Switch off inverter and remove consumer. Restart without consumer. Press the internal fuse back in by hand if triggered. Check cables and connections.DIY Safe
N/A
LED flashes slowly + double flash (Red)
Possible Cause: Fan fault
Check ventilation and fan blockage. Contact technical support if persistent.DIY Check / Tech Fallback
N/A
Inverter does not switch on or cuts out
Possible Cause: Blown fuse, loose terminal connections, or incorrect battery voltage.
Check and replace blown fuses, tighten terminal connections to max 15 N·m, and verify battery voltage matches rating label.DIY Safe
N/A
No output voltage (ignition off)
Possible Cause: Socket is switched on via the ignition, which is currently off
Switch on the ignition.DIY Safe
N/A
No output voltage (low battery)
Possible Cause: Battery voltage below 10V (720-012PP) or 20V (720-024PP), or below 11V (MSI212/412) / 22V (MSI224/424)
Charge the battery (start the engine).DIY Safe
N/A
No output voltage (thermal overload)
Possible Cause: Thermal overload or overheating, or inadequate cable connection (cross-section too small)
Switch off consumer unit, let the inverter cool down, ensure better ventilation, and check cable connections.DIY Safe
N/A
No output voltage (blown fuse)
Possible Cause: Faulty fuse in the inverter or vehicle
Have an electrician change the fuse.Professional Intervention Required
N/A
No output voltage, no LED lights up
Possible Cause: No contact to the battery or defective fuse (in the inverter or vehicle)
Check battery contact and fuse; replace as necessary.DIY Safe
N/A
No output voltage, green and red LEDs light, load too high/short circuit/incorrect wiring
Possible Cause: Load too high, short circuit, or incorrect electrical wiring
Switch off device, reduce load or eliminate short circuit, check electrical wiring, and switch device back on.DIY Safe
N/A
Warning signal / sound during operation
Possible Cause: Battery voltage below approx. 11V (12V models) or 22V (24V models), or poor/inadequate cable connection under load
Charge the battery, check cable connections and cross-section, and check for poor contact in the socket under load.DIY Safe
N/A
Device switches on and off repeatedly / cyclically (up to five times, then shuts down completely)
Possible Cause: Excessive or constant load too high
Switch off device, reduce load, and switch device back on.DIY Safe
N/A
Inverter switches off when the consumer is switched on
Possible Cause: Starting current of the connected device is too high
Compare device power requirements with the maximum power of the inverter, accounting for higher startup demands on motor-driven devices.DIY Safe
N/A
Status LED / Input Level flashes quickly (input voltage too high)
Possible Cause: Input voltage exceeds normal operating limits (>14.7V for 12V systems or >29.4V for 24V systems, up to shutdown threshold of 15.3V / 30.6V)
Check the input voltage and reduce it.DIY Safe
N/A
Status LED / Input Level flashes slowly (input voltage too low)
Possible Cause: Battery voltage has dropped below the low voltage shutdown threshold (10.5V for 12V models, 21.0V for 24V models)
Recharge the battery. Check cables and connections.DIY Safe
N/A
Status LED / Load Status flashes periodically or double-blinks (thermal overload)
Possible Cause: Internal temperature or cooler temperature exceeded the safety cut-off limit
Let the inverter cool down and improve ventilation before restarting.DIY Safe
N/A
Status LED / Load Status permanently/constantly lit red
Possible Cause: Short circuit in the consumer unit, total load higher than specified data sheet limits, or reversed polarity/incorrect wiring
Switch off the inverter, remove the consumer unit, and restart. If no error occurs, inspect the consumer for short circuits or excessive power draw. Check cables and connections.DIY Safe
N/A
Battery voltage display is in the red area (above or below normal)
Possible Cause: Battery voltage is outside operating limits, triggering over-voltage (OVP) or low voltage (UVP) protection
Check battery charge state and charging system. The inverter will switch off automatically.DIY Safe
N/A
Output power display goes into the red area
Possible Cause: Appliance power draw exceeds inverter limits or short circuit
Reduce connected load. The inverter will switch off automatically and trigger OLP.DIY Safe
N/A
Inverter switches off with OVP LED illuminated
Possible Cause: Over-voltage detected
Check battery charge state and charging system; reduce input voltage.DIY Safe
N/A
Inverter switches off with UVP LED illuminated
Possible Cause: Low input/undervoltage detected
Recharge the battery and check cables and connections.DIY Safe
N/A
Inverter switches off with OTP LED illuminated
Possible Cause: Inverter overheating
Let the inverter cool down and improve ventilation.DIY Safe
N/A
Inverter switches off with OLP LED illuminated
Possible Cause: Overloading or short-circuiting
Reduce connected load or eliminate short circuit.DIY Safe
N/A
Inverter fails to operate / No AC output
Possible Cause: Blown fuse, incorrect polarity connection, or discharged battery
Check battery voltage, inspect line fuse, verify correct DC polarity, and ensure the on/off switch is in the correct position (I for manual, II for remote, 0 for external switch).DIY Safe
N/A
Inverter overheats
Possible Cause: Blocked air inlets/outlets, poor ventilation, or loose terminal connections causing high resistance
Clear obstructions around ventilation openings, ensure proper clearance distances, and retighten terminal screws/nuts to a maximum torque of 15 N.m.DIY Safe