Truma Trumatic C 4002 / C 6002
The Trumatic C 4002 and C 6002 are hot-air liquid-gas combination heating systems with an integrated 12-litre hot water boiler. They provide thermostatically controlled room heating and water heating simultaneously or independently, with fan-assisted operation for use while driving.
Technical Specifications
Master Troubleshooting & Diagnostics Matrix
| Error Code / Indicator | Symptom / Meaning | Step-by-Step DIY Fix | Suggested Actions |
|---|---|---|---|
N/A | No control lamp lights up when the system is switched on (winter and summer operation). Possible Cause: Device fuse or vehicle fuse defective, open window above cowl (window switch), or low battery voltage. | Charge battery voltage (12 V), check all electrical plug connections and fuses, and close the window. | DIY Safe |
N/A | The green indicator lamp comes on when the equipment is switched on (using the ZUC timer), but the heater is not operating. Possible Cause: Open window above cowl (window switch). | Close the window. | DIY Safe |
N/A | The red monitor lamp flashes after the heating system has been switched on. Possible Cause: Battery voltage is too low (< 10.5 V). | Charge the battery. | DIY Safe |
N/A | About 30 seconds after the heating has been switched on, the red monitor lamp lights up and remains steady. Possible Cause: Gas cylinder or quick-closure valve in the gas line is closed, or air feed interrupted. | Check gas feed, check cowl for possible coverage, and if being used on boats, open the deck cowl. | DIY Safe |
N/A | Heating switches to Fault mode after an extended period of operation. Possible Cause: Hot-air outlets blocked, gas pressure regulator iced up, or butane content in the gas cylinder too high. | Check individual outlet apertures, use de-icing system controller (EisEx), and use propane (at temperatures below 10°C in particular, butane is unsuitable for heating purposes). | DIY Safe |
N/A | No control lamp lights up when the 230 V electrical operation system is switched on. Possible Cause: No supply voltage. | Check 230 V supply voltage and fuses. | DIY Safe |
N/A | When the heating system is switched off, the electrical safety/drain valve opens. Possible Cause: Outside temperature below 4°C or no 12 V power supply at the drain valve. | Switch the heating on (at temperatures of about 4°C and below the drain valve will open automatically). Check 12 V supply voltage and fuses. | DIY Safe |
N/A | The electrical safety/drain valve will no longer close, or water is dripping from the electrical safety/drain valve. Possible Cause: Outside temperature below 8°C, no 12 V power supply at the drain valve, or water pressure too high. | Switch the heating on (without heating operation, the drain valve will not close again until temperatures above 8°C have been reached), check 12 V supply voltage and fuses, and check pump pressure (max. 2.8 bar). If connected to a central water supply, use a pressure reducer to prevent pressures higher than 2.8 bar entering the boiler. If the issue remains unresolved, contact an authorized service agent. | DIY Check / Tech Fallback |
Frequently Asked Questions
Q: Can the heating be operated without water in the boiler?
Yes, heating operation is basically possible without restriction with or without water content.
Q: Why does the electrical safety/drain valve open by itself?
At temperatures below 4°C at the valve, or when the system loses 12V power, the safety valve opens automatically to drain the boiler and prevent frost damage.
Q: How do I fill the water boiler?
Close the safety/drain valve by lifting the control knob to position 'm', turn on the water pump power, and open the hot water taps until water flows continuously without air.
Q: Can I use the hot water for drinking?
No, the water in the boiler is not drinking water.